powerpack

ELECTRAVOLT 2.0

ELECTRAVOLT 3.0

80, 110, 140, 200 V

50, 100, 150, 200 V

Cat. No. E4100080

Cat. No. E4100050

Voltage range designed for optimal running
    of small vertical & horizontal gels

Size: 15 (b) x 7.5 (d) x 7.5 (h) cm
Negligible voltage dip on connecting
    to electrophoresis unit

Single output

Rated for Max current - 150 mA Corrosion resistant body





Complete Specifications
  Details Electravolt 2.0Electravolt 3.0
  Voltage Outputs 80 V
110 V
140 V
200 V
50 V
100 V
150 V
200 V
  Current Output upto 150 mA DCupto 150 mA DC
  Power (Wattage) 30 W30 W
  Voltage Adjustment Via rotary switchVia rotary switch
  Current Adjustment NoneNone
  Mode of Regulation Constant voltage, current limitedConstant voltage, current limited
  Voltage Indicator None None
  Timer None None
  Autorecovery on power failure
  Set point stays indefinitely
Yes Yes
  Operating temperature range 0°C to +40°C 0°C to +40°C
  Voltage input 230 rms, 50 Hz, single phase 230 rms, 50 Hz, single phase
  Frequency 47 Hz to 53 Hz 47 Hz to 53 Hz
  Transient supression provided Yes Yes
  Component details
    Mains switch
    Fuse
    Output socket
    Mains inlet

Illuminated rocker switch
1A, internal
4 mm female on front panel
2 pin on side panel

Illuminated rocker switch
1A, internal
4 mm female on front panel
2 pin on side panel
  Line regulation in CV mode Better than +/- 5% Better than +/- 5%
  Load regulation in:
  no load to full load variation (in CV mode)
Better than 10% for 10%-100% load variation or vice versa Better than 10% for 10%-100% load variation or vice versa
  Ripple and noise
  in CV mode
Less than 5% peak to peak at highest output voltage Less than 5% peak to peak at highest output voltage
  Overload protection None
Blinking light indicates overload
None
Blinking light indicates overload
  Short circuit protection Transient protection Transient protection
  Overvoltage protection None None
  Isolation
    - between AC input & DC output terminals
    - between DC output terminals and chassis

2.1KV AC for 1 min

500V AC for 1 min

2.1KV AC for 1 min

500V AC for 1 min
  Insulation
    - between DC output a& chassis
100 Mohms @ 50 DC 100 Mohms @ 50 DC
  Humidity tolerance upto 95% (non condensing) upto 95% (non condensing)
  Cooling
By normal convection, venting at the bottom and sides By normal convection, venting at the bottom and sides
  Dimensions of the body
  [measurement excludes projecting knobs, handles and switches]
150 mm (w)
x 75 mm (h)
x 75 mm (d)
150 mm (w)
x 75 mm (h)
x 75 mm (d)


EcoSep

Contact Us


Downloads:

Electravolt


Links:

FAQ
Site map
Downloads page


External Links:

TechnoSource